Franklin Electric Variable Frequency Drive, Series: GS, 200 - 230 V, 5 A, 0.75 kW, 1 hp, 50/60 Hz Input, 0 - 400 Hz Output, 3 -Phase, NEMA 1 Enclosure, 1.9 kVA VA, 14 - 122 deg F Ambient, 2.76 in W x 6.9 in H x 5.12 in D
Amperage Rating |
: |
5 A |
Dimensions |
: |
2.76 in W x 6.9 in H x 5.12 in D |
Enclosure Type |
: |
NEMA 1 |
Frequency Rating |
: |
50/60 Hz Input, 0 - 400 Hz Output |
HP Rating |
: |
1 hp |
Phase |
: |
3 |
Power Rating |
: |
0.75 kW |
Temperature Rating |
: |
14 - 122 deg F Ambient |
VA Rating |
: |
1.9 kVA |
Voltage Rating |
: |
200 - 230 V |
- Sensor less vector control - precise speed control and powerful high torque, up to 150% at 0.5 Hz, improves control with varying loads, auto tuning simplifies commissioning, sensor less mode also selectable
- Space vector modulation for superior motor life - super clean sine wave for cool running motors and high efficiency, minimizes heat losses in for long motor life
- Integrated pid - precise control to maintain flow-rate, pressure, temperature and more without any extra controllers, accepts 0 - 10 V, 4 - 20 mA analog signals and more
- Dynamic braking circuit - minimizes deceleration time on high inertia loads when used with braking resistors
- Built-in RS-485 communication - remote control and monitoring with other controllers (modbus standard)
- Ground-fault protection - superior equipment protection
- Cooling fan control - quiet, low noise operation; easy to replace fan module
- 95% Relative humidity maximum (non-condensing)
- 1000 m maximum, 5.9 m/sq-sec maximum altitude and vibration 1
- Control method - sensor less vector, V/F control (space vector PWM)
- Frequency setting resolution - digital reference: 0.01 Hz (below 99 Hz) and 0.1 Hz (100 Hz and over), analog reference: 0.03 - 50 Hz
- Frequency setting accuracy digital - 0.01% of maximum output frequency, analog: 0.1% of maximum output frequency
- V/F ratio - linear, square, user V/F
- Overload capacity - 1 min at 150%, 30 sec at 200% (with inverse characteristic proportional to time)
- Torque boost - auto, manual (0 - 15%)
- Assigned terminals - FX (forward), RX (reverse), BX (inverter gate blocking), RST (reset), JOG (jog)
- Eight Digital inputs programmable
- 0 - 10 V linear analog output
- Operator control - 4 digit LED display/keypad, terminals, ModBus communication
- Analog frequency setting - 0 - 10 V, 4 - 20 mA, digital: keypad, communication: ModBus
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Franklin_Electric_CI_001_GS2_Specification_Sheet.pdf