Gibson® Split System Heat Pump, Series: JT4BD, JT4BD-060K Model, 208 - 230 VAC, 34.3 A, 1/4 hp, 60 Hz, 1 -Phase, 60000 Btu/hr BTU, 3800 cu-ft/min, 10.5 EER, 13 SEER, HSPF: 8, 3/8 in Liquid, 7/8 in Suction Connection, R-410A Refrigerant, 34.3 A Fuse, 25.3 sq-ft Face Area, 16 Fins/in Coil Rating, 5 ton, 79 dB dBA, 1 -Stage, Steel, Galvanized, Polyester Urethane-Coated, 43-1/2 in H x 30-3/4 in W x 30-3/4 in D
Amperage Rating |
: |
34.3 A |
BTU Rating |
: |
60000 Btu/hr |
CFM Rating |
: |
3800 cu-ft/min |
Coil Rating |
: |
25.3 sq-ft Face Area, 16 Fins/in |
Connection Type |
: |
3/8 in Liquid, 7/8 in Suction |
Dimensions |
: |
43-1/2 in H x 30-3/4 in W x 30-3/4 in D |
EER Rating |
: |
10.5 |
Finish |
: |
Galvanized, Polyester Urethane-Coated |
Frequency Rating |
: |
60 Hz |
Fuse Rating |
: |
34.3 A |
HP Rating |
: |
1/4 hp |
HSPF Rating |
: |
8 |
Material |
: |
Steel |
Model |
: |
JT4BD-060K |
Number of Stages |
: |
1 |
Phase |
: |
1 |
Refrigerant Type |
: |
R-410A |
SEER Rating |
: |
13 |
Sound Level |
: |
79 dB dBA |
Tonnage |
: |
5 ton |
Voltage Rating |
: |
208 - 230 VAC |
- Design Series (4)
- Braze 13 SEER
- 26.2 A-rated load, 134 A locked rotor compressor, 1.46 A fan motor, 27.7 A total
- Copper tube/aluminum fin coils are designed to optimize heat transfer, minimize size and cost and increase durability and reliability
- Permanently lubricated condenser heavy-duty PSC motor for long-lasting reliability and quiet operation, requires no maintenance and is completely protected from rain and snow
- Complete metal wrapper - durable metal guard protects the coil from yard hazards and extreme weather
- Removable top grille assembly - allows ease of service from the top without disconnecting fan motor leads
- High pressure switch - protects against abnormally high system pressures, auto-reset feature prevents nuisance service visits
- Liquid line filter drier - included with unit, field installed
- One-piece top/orifice - designed for maximum airflow and quiet operation
- Five min restart time delay - when the units shuts down, a five min delay keeps the unit from restarting, eliminating the highest cause of compressor failure
- Suction accumulator - protection from liquid flood back and future compressor failures
- Hot gas muffler - reduces compressor noise and vibration
- Easy compressor and control access designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit
- Composite base pan absorbs sound and is corrosion-resistant, composite is also stronger and lighter than steel
- Fixed orifice - integrated in liquid line service valve for easy change out