Lochinvar® Knight XL Gas Fired Water Boiler, Series: KBN, 120 VAC, 60 Hz, 1 -Phase, 94 % AFUE, 160 - 8600 MBH Input, 752 MBH Output BTU, 5.7 gal Capacity, 1 in Gas, 2 in Water Connect, 4 in Air Inlet Connection, Natural Gas Fuel, Horizontal or Vertical Vent, 6 in Chimney/Breeching/Vent Size, Direct Spark Ignition, 654 MBH Net BTU Rating, Wall Mounting, 15-1/2 in W x 42-1/2 in H x 45-1/4 in D
AFUE Rating |
: |
94 % |
BTU Rating |
: |
160 - 8600 MBH Input, 752 MBH Output |
Capacity |
: |
5.7 gal |
Chimney/Breeching/Vent Size |
: |
6 in |
Connection Type |
: |
1 in Gas, 2 in Water Connect, 4 in Air Inlet |
Dimensions |
: |
15-1/2 in W x 42-1/2 in H x 45-1/4 in D |
Frequency Rating |
: |
60 Hz |
Fuel Type |
: |
Natural Gas |
Ignition Type |
: |
Direct Spark |
Mounting Type |
: |
Wall |
Net BTU Rating |
: |
654 MBH |
Phase |
: |
1 |
Vent Type |
: |
Horizontal or Vertical |
Voltage Rating |
: |
120 VAC |
- Smart system digital operating control, multi-colored graphic LCD display with navigation dial and soft key
- 3-boiler set point temperature inputs
- Built-in cascading sequencer for upto 8-boilers - multiple size boiler cascade, lead lag, efficiency optimization and front end loading capability with copper fin II
- Outdoor reset control with outdoor air sensor
- Programmable system efficiency optimizers - night setback, DHW setback, anti-cycling, outdoor air reset curve, ramp delay, boost temperature and time
- 3 pump control - system pump with parameter for continuous operation, domestic hot water pump
- Domestic hot water prioritization - DHW tank piped with priority in the boiler loop, DHW tank piped as a zone in the system with the pumps controlled by the smart system, DHW modulation limiting
- Building management system integration - 0 - 10 VDC input to control modulation or set point, 0 - 10 VDC modulation rate output, 0 - 10 VDC input to enable/disable call for heat
- Access to BMS settings through graphic LCD display
- High-voltage terminal strip are 3-sets of pump contact
- Low voltage terminal strip - 24 VAC device relay, proving switch contacts, flow switch contacts, alarm on any failure contacts, run-time contacts, DHW thermostat contacts, three-space heat thermostat contacts, system sensor contacts, DHW tank sensor contacts, outdoor air sensor contacts, cascade contacts
- 0 - 10 VDC BMS external control contact, 0 - 10 VDC boiler rate output contacts, 0 - 10 VDC variable speed system pump signal input, 0 - 10 VDC signal to control variable speed boiler pump, Modbus contacts
- Time clock
- Data logging - hrs running, space heating, domestic hot water, ignition attempts, last 10-lockouts
- Low water flow safety control and indication, password security and customizable freeze protection parameters
- Modulating burner with 5:1 turndown, low-NOx operation, sealed combustion, low gas pressure operation
- ASME stainless steel heat exchanger, 30 lb/sq-in ASME pressure relief valve, 160 lb/sq-in working pressure
- Smart system control, condensate trap, automatic reset high limit, adjustable high limit with manual reset, boiler circulating pump, wall-mount bracket, zero clearances to combustible materials
- PVC, CPVC, polypropylene or SS venting up to 100 ft
- 10 years limited warranty