Contact 1-800-314-3578

  1. pin-int

PENNCO KWB307532110207 ERP_015440

PENNCO KW II KWB307532110207 Oil Fired Water Boiler with Tankless Coil, 0.856 AFUE, 105 MBH Input, 92 MBH Heating BTU

  • Manufacturer: BDR Thermea Group
  • Brand Name: PENNCO
  • Part Number: ERP_015440
  • MPN: KWB307532110207
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

The Pennco KW series II now features a new Honeywell high limit and circulator relay control with digital temperature display and diagnostics. In the less coil version, the control monitors water temperature and delays the burner starting until any residual heat has been transferred. Thermal purge logic measures rate of temperature change inside the boiler and delays burner firing accordingly. This maximizes efficiency by turning on the burner only when needed. In the with coil version the low limit control seeks maximum temperature to satisfy domestic hot water call bypassing thermal purge logic.

PENNCO Oil Fired Water Boiler with Tankless Coil, Series: KW II, 3KW0.75 Model, 0.856 AFUE, 105 MBH Input, 92 MBH Heating BTU, 80 MBH Net BTU Rating, 0.75 gal/hr, Oil Fuel, Chimney Vent, 8 x 8 in Square, 15 ft H Chimney Size, 3 -Section, Steel, 19-1/2 in W x 36 in H x 17-3/4 in D

AFUE Rating      :      0.856
BTU Rating      :      105 MBH Input, 92 MBH Heating
Chimney Size      :      8 x 8 in Square, 15 ft H
Dimensions      :      19-1/2 in W x 36 in H x 17-3/4 in D
Flow Rate      :      0.75 gal/hr
Fuel Type      :      Oil
Material      :      Steel
Model      :      3KW0.75
Net BTU Rating      :      80 MBH
Number of Sections      :      3
Vent Type      :      Chimney
  • Assembled boiler with insulated jacket
  • Completely installed and wired Beckett AFG Series oil burner equipped with oil nozzle, primary control, CAD cell , PSC motor, interrupted-duty ignition and clean cut pump
  • Flue brush
  • Target wall (vacuum formed refractory ceramic fiber)
  • Durablanket insulation chamber
  • Barometric draft control 6 in
  • Combination pressure temperature gauge
  • Circulator pump wired with 5 in harness for supply or return-mounting in the field
  • 3/4 in boiler drain valve
  • 30 lb/sq-in ASME pressure relief valve
  • Extra boiler tap for expansion tank or air elimination
  • 20 years limited heat exchanger warranty