TEMPSTAR® Package Rooftop Air Conditioner, Series: RAS, 20 ton Nominal, 242000 Btu/hr Cooling BTU Rating, 460 VAC, 18.6/14.7 A Rated Load, 125/95 A Locked Rotor, 24.2 kW, 1/4 hp Condenser Fan, 690 - 863 rev/min Evaporator Fan, 60 Hz, 3 -Phase, (2) Scroll Compressor, Configuration: Vertical, 6000 - 10000 cu-ft/min, 10 EER, R-410A Refrigerant, 86.5 dBA, Belt Drive, Evaporator Coil - 22 sq-ft Face Area, 15 Fins/in Coil Rating, Pre-Painted, Gray, 141-1/2 in L x 86-5/8 in W x 49-3/8 in H
Amperage Rating
:
18.6/14.7 A Rated Load, 125/95 A Locked Rotor
CFM Rating
:
6000 - 10000 cu-ft/min
Coil Rating
:
Evaporator Coil - 22 sq-ft Face Area, 15 Fins/in
Color
:
Gray
Compressor Type
:
(2) Scroll
Configuration
:
Vertical
Cooling BTU Rating
:
242000 Btu/hr
Dimensions
:
141-1/2 in L x 86-5/8 in W x 49-3/8 in H
Drive Type
:
Belt
EER Rating
:
10
Finish
:
Pre-Painted
Frequency Rating
:
60 Hz
HP Rating
:
1/4 hp Condenser Fan
Nominal Capacity
:
20 ton
Phase
:
3
Refrigerant Type
:
R-410A
Rotational Speed
:
690 - 863 rev/min Evaporator Fan
Sound Level
:
86.5 dBA
Voltage Rating
:
460 VAC
Wattage
:
24.2 kW
One-piece, high efficiency electric cooling with a low profile, prewired, tested and charged at the factory, full perimeter base rail with built-in rigging adapters and fork truck slots
Pre-painted exterior panels and primer-coated interior panels tested to 500 hr salt spray protection, fully insulated cabinet
Single or dual scroll compressor with internal line-break overload protection
All units have high/low pressure switches
2 in disposable fiberglass-type return air filters in dedicated rack with tool less filter access door
Refrigerant circuits contain a liquid line filter drier to trap dirt and moisture
Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes
Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 standard, sloping design, side or center drain
Belt drive evaporator fan motor and pulley combinations
Access panels with easy grip handles provide quick and easy access to the blower and blower motor, control box and compressors
No-strip screw system has superior holding power and guides screws into position while preventing the screw from stripping the units metal
Outdoor temperature cooling operation range up to 115 deg F and down to 25 deg F using winter start kit
Fixed orifice metering devices on all models to precisely control refrigerant flow
Large, laminated control wiring and power wiring drawings are affixed to unit to make troubleshooting easy
Capable of thru-the-base or thru-the-curb electrical routing, one-point electrical connections
5 years limited warranty on compressor and one-year limited warranty on parts