Thermo-Dynamics Oil Fired Water Boiler with Coil, Series: S, S110 Model, 0.83 AFUE, 154000 Btu/hr Input, 129000 Btu/hr Heating BTU, 112000 Btu/hr Net BTU Rating, 1.1 gal/hr, 1-1/4 in Supply/Return Connection, Oil Fuel, Chimney Vent, 15 gal Input, 8 x 8 in Square, 15 ft H Chimney Size, 6 in Vent Dia, Steel, 21-1/4 in W x 38-1/2 in H x 21-1/4 in D
AFUE Rating |
: |
0.83 |
BTU Rating |
: |
154000 Btu/hr Input, 129000 Btu/hr Heating |
Chimney Size |
: |
8 x 8 in Square, 15 ft H |
Connection Type |
: |
1-1/4 in Supply/Return |
Dimensions |
: |
21-1/4 in W x 38-1/2 in H x 21-1/4 in D |
Flow Rate |
: |
1.1 gal/hr |
Fuel Type |
: |
Oil |
Input Capacity |
: |
15 gal |
Material |
: |
Steel |
Model |
: |
S110 |
Net BTU Rating |
: |
112000 Btu/hr |
Vent Diameter |
: |
6 in |
Vent Type |
: |
Chimney |
- Allows the installer to size the boiler more closely to the home heating needs for greater efficiency, the lowest firing rate, 0.85 - 87000 Btu/hr, is necessary for many well insulated homes where the heat loss is minimal
- 1 in Thick pyrolite ceramic fiber combustion chamber, fast warm-up - glows to incandescence in 11 - 17 sec, large diameter allows brushing flue passages without punching through chamber
- S-series operates at 140 lb/sq-in pump pressure for better fuel atomization, thereby having the ability to tolerate fuel oil with heavy ends
- S-series is standard with a state-of-the-art, solid state ignition system, making it more tolerant to low voltage or voltage fluctuations
- Integrated ignition
- Electronic delay with solenoid valve clean-cut fuel pump
- S-series has exceptional water content, the first size has 16 gal of water, high water volume and placement of the coil in the hottest part of the boiler allows for maximum coil performance
- The unique tube design of the S-series boiler heat exchanger slows the flue gases, allowing for more effective heat transfer without the need for extreme baffling often seen in other vertical tube boilers
- Each boiler is constructed and hydrostatically tested in accordance with ASME boiler code, the capacity and efficiency are rated in accordance with the standards of the institute of boiler and radiator manufacturers (IBR)
- Built-in air scoop purges air from the system providing a quiet, trouble-free hot water heating system without the use of external devices
- Extended flange coil is away from the boiler for easy accessibility, use of ribbed neck carriage bolts eliminates the problems encountered when a weld stud is broken during servicing, large coil plate allows for a greater gasket sealing area
- Extended weld fittings of SA106 Schedule 80 seamless pipe extend beyond the jacket and allow the service technician or homeowner to see small leaks that, if undetected, could later damage the boiler shell and void the warranty
- Easy cleaning and maintenance accessibility to combustion areas and the open tubes make it easy for the service technician to thoroughly clean the boiler
- Flush jacket, altitude, temperature and pressure gauge, ASME relief valve, thankless heater - 3 gal/min, factory assembled, wired and packaged, 3450 rev/min high-speed flame retention oil burner, interrupted primary ignition, hydronic triple aquastat relay, 007 circulator pump, brass boiler drain valve
- Lifetime limited warranty