Yaskawa AC Drive, Series: P1000, 380 - 480 VAC, 24 A Input, 23 A Output, 11 W kW, 15 hp, 50/60 Hz, 3 -Phase, NEMA 1 Enclosure, 28.4 kVA Power Supply, 17.5 kVA VA, -10 to 40 deg C Ambient, 5.51 in W x 11.81 in H x 6.57 in D
Amperage Rating |
: |
24 A Input, 23 A Output |
Dimensions |
: |
5.51 in W x 11.81 in H x 6.57 in D |
Enclosure Type |
: |
NEMA 1 |
Frequency Rating |
: |
50/60 Hz |
HP Rating |
: |
15 hp |
Phase |
: |
3 |
Power Rating |
: |
11 W kW |
Power Supply |
: |
28.4 kVA |
Temperature Rating |
: |
-10 to 40 deg C Ambient |
VA Rating |
: |
17.5 kVA |
Voltage Rating |
: |
380 - 480 VAC |
- LCD operator with real time clock: 5-line, 16-character alpha-numeric display with time and date stamping for events, along with timer controls for starting, stopping, and speed changes without the need for external controls
- Application macros: choose from pre-configured fan and pump setup macros to match the application for quick and easy set up
- Underload detection: monitors load and will shut system down in the event of a fan belt or pump shaft breakdown
- Parameter storage and removable terminal board: allows for easy replacement of control card without removing control wires, and stores all drive settings without the need for a copy device
- PI process control - maintains a set point for closed loop control of fans and pumps for pressure, flow, or temperature regulation, and eliminates the need for a closed loop output signal from a process controller, independent PI to control an external device in the system
- Power quality - built-in DC reactors (30 hp and larger) provide input harmonics benefit, and protection from input disturbances, integrated 12 pulse version (480 V, 40 hp and larger) provides a cost-effective solution for low harmonics
- Dynamic noise control - monitors the load at all times and reduces the output voltage automatically, reducing motor audible noise
- Standard I/O - (8) multi-function digital inputs (24VDC), (3) multi-function analog inputs (0 - 10 VDC, 4 - 20 mA), (1) multi-function pulse input, (1) fault relay output, (1) multi-function relay, (2) multi-function relay outputs, (2) multi-function analog outputs (0 +/- 10 VDC, 4 - 20 mA), sensor feedback power supply (plus 24 VDC at 150 mA supply)
- Variable torque (square of percent speed) continuous load capacity
- 120% for 60 sec intermittent load capacity
- -15 to 10% allowable voltage fluctuation
- +/- 5% allowable frequency fluctuation
- With fan
- Electronic thermal overload relay
- 2 - 15 kHz carrier frequency
-
Catalog